Documents:
This type of construction, is used in applications where the temperature exceeds 200 ° C, and therefore, is necessary to leave space between the connecting flange, and the terminals of the resistors, in order to avoid damaging the Sealed.
They are a good solution for computers whose flange is not too large, and the number of rods to be welded too high. Then, or also depending on the application, can make use of the GCB-C.
Main Features
• Power to customer
• Three-phase supply to 750 V
• Specific load up 16 W/cm². Recommended loads by application
1 at 3 W/cm² – Air, stoves
1,2 W/cm² – Heavy fuel oil
2 at 4 W/cm² – Thermal oil, fuel oil or light media
6 at 8 W/cm² – Water
• armored elements in a "U"
• Material of the cover tube in stainless steel AISI 321, AISI 316L, Incoloy®-800, Incoloy®-825 ó Cobre Nickel • standard tube diameters: 8mm, Ø10, Ø12'5, Ø16 mm
• Longitude Llano Platinum maxim: 3300 mm for all lengths
• fully standardized Bridas: DIN – ANSI steel or stainless steel • Junction boxes with Degree moisture protection to IP-66
• Temperature Control by Thermostat, limiter, probe the thermocouple probe Pt100