Documents:
Main Features
• Certificate ATEX Ex II 2 G/D EEx’d’ IIC T3 a T6 , to EN 50014 and EN 50018
• aluminum junction box IP67 protected against moisture
• Sensor Built temperature
• Valid for Ambient temperature up to -40 °C
• Coupling by heating Plug 2″ – 2″¼ – 2″½
• Design for horizontal installation only. Vertical installation available on request.
• Junction Box: Aluminium box with a maximum of 2 tickets for cables, making Land and internal and external screw cap. ATEX II 2 G/D EEx’d’ IIC T4 to T6 with option of T3 to T6 when the junction box is separated from the stopper coupling (tipo RFA/SO). Degree IP67 protection against moisture.
• heating elements: Up to three tubular elements, resistance wire of Alloy The NiCr 80/20, Magnesium Oxide and compacted Funda tubular Copper, Steel, Monel, Inconel, Incoloy 800/825, stainless steel Titanio, soldiers to plug welded with input (brazing) welding without the contribution (TIG) depending on the application.
• Controles: The RFA default heaters incorporate overtemperature protection. Optionally you can add other devices such as thermostats temperature, termorresistencias the thermocouples.
• Coupling: Within the limits of design, you can specify the Thread and coupling the plug material.
Typical applications
• Warming of water or oil
• Tank cleaning and rinsing
• Equipment Process • System transfers heat
• Calderas
• Frost protection