Documents:
Main Features
• Certificate ATEX Ex II 2 G/D EEx’d’ IIC T3 a T6 , to EN 50014 and EN 50018
 • aluminum junction box IP67 protected against moisture
 • Sensor Built temperature
 • Valid for Ambient temperature up to -40 °C
 • Coupling by heating Plug 2″ – 2″¼ – 2″½
 • Design for horizontal installation only. Vertical installation available on request.
 • Junction Box: Aluminium box with a maximum of 2 tickets for cables, making Land and internal and external screw cap. ATEX II 2 G/D EEx’d’ IIC T4 to T6 with option of T3 to T6 when the junction box is separated from the stopper coupling (tipo RFA/SO). Degree IP67 protection against moisture.
 • heating elements: Up to three tubular elements, resistance wire of Alloy The NiCr 80/20, Magnesium Oxide and compacted Funda tubular Copper, Steel, Monel, Inconel, Incoloy 800/825, stainless steel Titanio, soldiers to plug welded with input (brazing) welding without the contribution (TIG) depending on the application.
 • Controles: The RFA default heaters incorporate overtemperature protection. Optionally you can add other devices such as thermostats temperature, termorresistencias the thermocouples.
 • Coupling: Within the limits of design, you can specify the Thread and coupling the plug material.
Typical applications
• Warming of water or oil
 • Tank cleaning and rinsing
 • Equipment Process • System transfers heat
 • Calderas
 • Frost protection


